Posted by admin | Posted in Parts And Stuff | Posted on 27-11-2009
Tags: borehole, level, pump, rv water pump switch, valve, water, water pump switch, water pump switch adjustment, water pump switches, well water pump switch
Water Pump Switch
![]() |
![]() Portable RV Waste Pump US $165.00
|
![]() RV DIGITAL TOUCH TANK WATER PUMP ELECTRIC LP PANEL US $132.00
|
![]() RV Water Pump Switch with Red Light New US $15.29
|
![]() Shurflo Single Fixture Water Pump 100 009 21 10 GPM 12 volt US $51.00
|
![]() Shurflo RV water pump 200 220 39 US $33.55
|
![]() Shurflo RV water pump 2088 403 444 US $31.01
|
![]() Fiamma Superflusso S 12 RV Trailer Camper Boat Water Pump Pressure Regulator NEW US $150.00
|
![]() Sewer Solution Holding Tank Dump System Sewersolution US $99.00
|
![]() Shurflo Smart Sensor Extreme Series 57 RV Water Pump US $175.00
|
![]() JRV RV TANK MICRO MONITOR SYSTEM BATTERY WATER WASTE US $34.99
|
![]() FLOJET 12v Fresh Water On Demand Pump RV Marine 29 GPM Camper Trailer US $49.95
|
![]() SHURflo 28 Potable Water Pump US $86.77
|
![]() Shurflo 12V 28 GPM RV Trailer Camper Water Pump US $65.00
|
![]() SHURflo Extreme Series Smart Sensor 57 Water Pump US $257.00
|
![]() FLOJET 18555 000 Portable Waste Water Pump Kit w Case RV Trailer Motorhome US $207.59
|
![]() NEW BATH SHOWER WATER PUMP WALL ON OFF SWITCH CAMPER US $10.99
|
![]() FLOJET Portable RV Waste Water Macerator Pump Kit Brand New Trailer Camper US $199.95
|
![]() ShurFlo Premier Pump 28gpm 45psi switch RV water pump US $20.50
|
![]() Micro Monitor for RV holding tanks made by KIB US $24.95
|
![]() ShurFlo Smart Sensor Extreme 57 GPM Water Pump US $179.98
|
My brand new well water pump is acting incorrectly?
I just replaced my submersable well water pump, the wire that connects the pump, the d switch, and the Water Tank. Everything was installed correctly and with the help of a licensed plumber. While the D switch is closed (providing power to the pump) the pump will run for about 5 seconds then shut off for about one minute. It will continue this process until the system attains proper pressure and the D switch will open, shutting off power to the pump. The pump is brand new. Why, when power is being supplied does the pump cut on and off? We have tested the current at the well head and it shows that 230 is being supplied the whole time that the D switch is closed, which is correct.
I think we have it figured out. We have 230 volts running to a 115 pump. Wrong pump. Boy do i feel stupid.
I had one doing this similarly. The well was out of water or the pump may be too high in your case. The pump has a thermal cut out that is cutting out because it is protecting itself from over heating. once it cools a bit the thermal resets and it will pump again for a short time till it gets hot again. Perhaps this is your problem it was mine. I had to drill a new well. I assume you know there are 120 volt pumps out there be sure what the old one was. 220 probably would have cooked it by now anyway. Take the cap off and listen for the pump sound if it is out of the water you will be able to hear it if not to deep.



US $165.00





















